A pilot light on a gas stove going off and on repeatedly can be caused by a few different factors. Some potential reasons include:

  1. Thermocouple issues: The thermocouple is a safety device designed to detect whether the pilot flame is burning. If the thermocouple is faulty or misaligned, it may not detect the pilot flame correctly and can shut off the gas flow intermittently as a safety measure.

  2. Dirty or clogged pilot assembly: A pilot light that is dirty or clogged with debris might not burn consistently. This can cause it to go out and relight repeatedly.

  3. Gas pressure problems: If there are fluctuations in the gas supply or if the gas pressure is not stable, the pilot light may struggle to stay lit.

  4. Drafts or air flow: Strong drafts or air currents near the stove can blow out the pilot light flame, causing it to relight and then go out again.

  5. Gas supply issues: Problems with the gas supply line or gas valve can also result in the pilot light going out and relighting.

  6. Faulty safety valve: The safety valve on the gas stove may be malfunctioning, leading to an intermittent pilot light.

  7. Thermostat issues: In some cases, problems with the stove's thermostat or control board can cause the pilot light to cycle on and off.

If you encounter a situation where the pilot light keeps going off and on, it's important to address the issue promptly and ensure proper functioning of the stove for safety reasons. For gas-related issues, it's best to seek assistance from a qualified gas appliance technician to diagnose and fix the problem properly. Gas appliances can be dangerous if not handled correctly, so it's essential to let a professional handle any repairs or maintenance.